EDGAR WiFi: WiFi to RS232 or RS485 converter

Product code: EDGAR_Wifi_EU
Warranty: 3 years
VAT: 21%
Price inc VAT: 186.34 €
Price ex VAT: 154 €

Description

WiFi serial server with RS232 / RS485 port featuring V-out power output, that can power your external device and remotely turn it on and off.

What makes Edgar unique?

  1. It has a controlled V-OUT voltage output, that can power an external device and remotely turn it on and off. The VOUT output can be 5, 9, 12 or 24 V and can be controlled via WEB or HTTP GET.
  2. HTTP GET communication allowing easy access to the serial port from a WEB server.
  3. Wide range of power voltage 11 – 58 V DC.
WiFi Edgar block scheme

Connection diagram

A classic TCP server, TCP client or UDP can be used for communication. In addition to standard communications, Edgar WiFi can send packets from / to the serial line via HTTP GET. The data packet can be sent as HTTP GET request from the web server. Similarly, if the data are sent to a serial line – e.g. from a connected bar code reader - the converter can send the data to the web server as HTTP GET request.

Edgar WiFi comes in a robust metal chasis and can be optionally mounted to a DIN rail.

WiFi converter applications

  • Connecting serial devices to your Wi-Fi.
  • Wireless communication with remote devices over the Internet.
  • Legacy devices can be connected easily to a computer network.
  • Cable management improvement - Wi-Fi connection to Ethernet.

WiFi Edgar converter features

  • Converts serial line RS232/RS485 to WiFi
  • Virtual serial port - an option to use Edgar’s serial port the same way as computer’s serial port
  • Powered from an external power supply 11 – 58 V
  • Power input is galvanically isolated from other parts of the device
  • Power output for powering an external device can be 5, 9, 12 or 24 V
  • Easy configurations using web interface
  • TCP, UDP and HTTP GET protocols
  • User selectable interface RS232 or RS485 (DIP switch)
  • Used signals RS232: RxD, TxD, RTS, CTS, GND
  • Used signals RS485: RxTx+, RxTx-
  • Indications for power, data transfers, connections and WiFi activity
  • Package contents: converter, 2 dB antenna, power supply 15 V.

Power Output VOUT

VOUT power output can power the connected device as well. Therefore, no additional power supply is needed. Power output can be switched on or off using the web interface or by HTTP GET, thus a power consumption can be decreased or the attached device can be restarted.

Power output is DC and the output voltages can be selected using a DIP switch on the side of the device. You can choose from the following options:

  • 5 V / max. 630 mA
  • 9 V / max. 350 mA
  • 12 V / max. 260 mA
  • 24 V / max. 130 mA

How does HTTP GET work in a WiFi to a serial port converter?

This feature allows data from the serial port to be sent as HTTP GET requests to a remote server. In the reverse direction, the data from the remote server can be sent to the serial line directly by replying to the GET request sent by the converter.

HTTP GET request and response

Edgar sent GET to the server and received a reply with data that is to be sent back to serial port

The connection can also be initiated from remote server side. The server sends HTTP GET to the set.xml script in the converter. Data can be sent as an ASCII character string or using hexadecimal form as binary data.

HTTP GET from server

Edgar received HTTP GET reply from the server with data, that should be sent to serial line

HTTP GET communication can be optionally secured with 128bit AES encryption.

Images




Files:

Downloads


papouch.pdfDocumentation

Compete documentation of Edgar ETH and Edgar WiFi

File size: 93 kB

Date: 07-19-2018

Download

lantronix-redirector.ziplantronix-redirector.zip

Virtual serial port (Lantronix Com Port Redirector). The archive contains version 4.3.0.3 for:
x86 (32bit): Windows XP, 2003 Server, Vista, 7, 8, and 2008 Server
x64 (64bit): Windows Vista, 7, 8, and 2008 Server
Uninstall any previous versions of the CPR in Windows Add/Remove Programs before installing version 4.3.0.3!

File size: 525 kB

Date: 07-19-2018

Download


Do you have any question or a suggestion? We would like to hear it!


If you have any question, suggestion or just a note, we are pleased to hear all about it! Just write it in the following form and send it, simple as that. You can also contact us or our distributor by phone or e-mail, all can be found in contacts.




ERROR